Quantcast
Channel: VMware Communities : Blog List - All Communities
Viewing all articles
Browse latest Browse all 3135

MCA error detected via CMCI

$
0
0

Condition:- Cisco UCS B200 M3

 

 

cpu13:5344825)MCE: 1020: cpu13: MCA error detected via CMCI (Gbl status=0x0): Restart IP: invalid, Error IP: invalid, MCE in progress: no.

cpu13:5344825)MCE: 190: cpu13: bank7: status=0x8c00004000010091: (VAL=1, OVFLW=0, UC=0, EN=0, PCC=0, S=0, AR=0), Addr:0x1421652080 (valid), Misc:0x42389a00 (valid)

2018-03-16T12:36:38.906Z cpu13:5344825)MCE: 199: cpu13: bank7: MCA recoverable error (CE): "Memory Controller Read Error on Channel 1."

 

CIMC | Processor IERR #0x99 | Predictive Failure asserted | Asserted

5:2018 Mar 16 23:13:53 GMT:3.1(21d):selparser:1724: selparser.c:706: # DA 01 00 00 01 02 00 00 B1 4F AC 5A 20 00 04 24 95 00 00 00 7F 05 FF FF # 1da | 03/16/2018 23:13:53 | CIMC | Platform alert LED_BLADE_STATUS #0x95 | LED color is amber | Asserted

 

 

CPU 1 : MCA_ERR_SRC_LOG : 0xc0000000

CPU 2 : READ MCA_ERR_SRC_LOG Register : FAILED : RetVal = 0 : CC = 0x81

 

 

Solution:- replace faulty system board along with TPM.


Viewing all articles
Browse latest Browse all 3135

Trending Articles